4th axis cable - interface Detron Rotary table to Dugard VMC1000

Posted on 27th January 2021

This is a 4th axis cable built to interface a Detron Rotary table with Heidenhain motor onto a Dugard VMC1000 with Siemens 828D control.

This was a bit of a challenge with added complexities with the control needing more confirmation inputs than the Detron can give.

4th Axiz Cable for Interface

We overcame it by modifying the PLC to accommodate and retro fitting relays to invert signals.

We are Siemens specialists and keep a large stock of hardware and are also invested in repairing Siemens hardware where we can, please contact us for further details.